Hello. Use this guide to review emergency lighting testing at rented, commercial and communal properties in Conwy and Denbighshire.
Emergency lighting helps people leave a building safely if the normal lighting supply fails. It is particularly important in corridors, stairwells, shared entrances, commercial premises and other escape routes.
Landlords, letting agents, property managers and businesses should maintain a clear testing schedule. They should also keep accurate records and arrange professional inspection when faults are identified.
This article provides practical guidance. It is not legal advice. The requirements for your property may depend on its use, layout, occupancy, fire risk assessment, licensing conditions and existing emergency lighting system. Check the applicable premises requirements before relying on a testing schedule.
Where emergency lighting may be required
Emergency lighting is commonly installed in:
- Houses in multiple occupation (HMOs).
- Communal areas in blocks of flats.
- Shared corridors, landings and staircases.
- Commercial buildings.
- Offices, shops and public buildings.
- Care, education and healthcare premises.
- Industrial buildings and warehouses.
- Buildings with enclosed or complex escape routes.
A single private dwelling may not require the same emergency lighting arrangement as a commercial property or HMO. However, shared areas and escape routes can create additional responsibilities for the landlord, freeholder, managing agent or other responsible person.
Start by reviewing:
- The building’s fire risk assessment.
- The emergency lighting design and installation records.
- HMO licensing or local authority requirements.
- The system manufacturer’s instructions.
- Previous inspection and testing certificates.
- Any recommendations from a fire risk assessor or inspecting body.
Local expectations can vary. Contact the relevant council or competent fire safety adviser if you are unsure what applies to your property.
What emergency lighting does
Emergency lighting operates when the normal lighting supply fails. It can help occupants:
- Identify escape routes.
- Find staircases and changes in level.
- Locate final exit doors.
- See fire safety equipment.
- Avoid obstructions and trip hazards.
- Leave the building in a controlled manner.
- Reach a place of safety.
Exit signs and emergency luminaires must remain visible and unobstructed. A fitting that is present but not working does not provide adequate protection.
Routine visual checks
Routine checks should form part of normal property management visits. This is especially important for HMOs, communal buildings and commercial premises with regular inspections.
Walk the relevant escape routes and look for:
- Emergency fittings that are damaged or loose.
- Exit signs that are missing or obscured.
- Fault indicators on central battery systems.
- Charging LEDs that are not illuminated.
- Dirty or covered diffusers.
- Signs of water ingress or impact damage.
- Changes to walls, partitions or room layouts.
- Stored items blocking corridors or exits.
- Lighting that appears dim, flickers or fails to operate.
Record defects when you find them. Do not assume that a small fault can wait until the next annual inspection.
A visual check is not a replacement for a functional test. It is an early warning process that helps identify problems between formal tests.

Monthly emergency lighting testing
A monthly functional test is commonly known as a flick test. It simulates a failure of the normal lighting supply for a short period.
The exact test method depends on the equipment. It may involve:
- A test key switch.
- An integral test button.
- A local emergency lighting test facility.
- A central control panel.
- A managed testing system.
During the test, check that:
- Each emergency luminaire illuminates.
- Exit signs remain clearly visible.
- Fittings do not flicker or fail to start.
- The correct areas are covered.
- The normal supply returns correctly.
- Charging indicators return to their normal condition.
The test should be completed by someone who understands the system and can identify obvious faults. A landlord or site manager may complete routine testing where they have suitable instruction and competence.
Do not operate equipment if doing so could create a risk. Follow the manufacturer’s instructions and arrange professional support where necessary.
Record the following information:
- Date of the test.
- Name of the person completing it.
- Areas or circuits tested.
- Result for each area or fitting.
- Faults identified.
- Temporary measures put in place.
- Repairs requested or completed.
- Date of any retest.
Annual full-duration testing
The annual test checks whether the emergency lighting batteries can support the system for its rated duration. Three hours is common, but the required duration depends on the system design and the applicable standard.
A full-duration test can affect the availability of emergency lighting while the batteries discharge and recharge. Plan the work carefully. Consider:
- Occupancy levels.
- Building opening hours.
- Alternative lighting.
- Security arrangements.
- Access to all rooms and escape routes.
- The time required for batteries to recharge.
- Any vulnerable occupants or tenants.
A competent contractor should normally complete the annual service and full-duration test. The inspection should consider the condition and operation of the system, not just whether individual lamps turn on.
The contractor may check:
- Emergency luminaires.
- Exit signs.
- Batteries and charging units.
- Test switches.
- Central battery equipment.
- Escape routes and open areas.
- Mounting positions.
- Obstructions and changes to the building.
- Fault indicators.
- System records and previous defects.
Request a written report or certificate after the test. Keep it with the property’s fire safety records.
Keeping an effective fire safety logbook
Good records provide a clear history of testing, faults and remedial work. They also help property managers demonstrate that checks are being completed consistently.
Your records should include:
- Routine visual check entries.
- Monthly functional test results.
- Annual full-duration test certificates.
- Fault reports.
- Repair invoices.
- Replacement details.
- Retest results.
- Contractor details.
- Recommendations for future work.
- Copies of relevant fire risk assessment information.
Use a paper logbook or a suitable digital system. The format matters less than accuracy and consistency.
Do not record a test as complete if some fittings were not checked. Identify the affected areas and arrange follow-up action.

Common emergency lighting faults
The following faults are frequently identified during emergency lighting testing:
Failed batteries
Rechargeable batteries lose capacity over time. A fitting may illuminate during a brief monthly test but fail during a longer discharge test.
Failed lamps or LED modules
An emergency light may have a failed lamp, LED module or driver. Some modern fittings require replacement of the complete module.
Damaged fittings
Impact, damp, corrosion and poor installation can affect the safety and reliability of a fitting.
Obscured exit signs
New partitions, stored goods, decorations or building alterations can block the view of an exit sign.
Faulty test switches
A damaged or inaccessible test switch can prevent routine testing.
Charging faults
A fitting may not recharge correctly because of a power supply issue, charger fault, wiring problem or battery failure.
Incomplete coverage
Changes to the building layout can leave new corridors, rooms or staircases without suitable emergency lighting.
Missing records
A system may be working, but incomplete records make it difficult to confirm what has been tested and when.
Arrange a competent inspection if you find repeated failures, battery problems, unexplained fault indicators or changes to the building layout.
When to use a competent contractor
Use a qualified and competent contractor for work that requires technical knowledge, electrical isolation, fault diagnosis or certification.
Professional support is recommended for:
- Annual full-duration testing.
- New emergency lighting installations.
- System alterations.
- Battery replacement.
- Central battery systems.
- Repeated test failures.
- Electrical supply faults.
- Emergency lighting design reviews.
- HMO licensing documentation.
- Properties with complex or high-risk escape routes.
- Buildings where records are missing or inconsistent.
Emergency lighting testing should be coordinated with wider property safety work. However, it should not be treated as a substitute for an Electrical Installation Condition Report (EICR). These are separate inspections with different purposes.
Dragon provides electrical testing services for commercial, industrial, public sector and residential customers. Our team can also support wider fire services and planned maintenance requirements.
A practical checklist for landlords in Conwy and Denbighshire
Use this checklist to organise your 2026 maintenance programme:
- Confirm whether emergency lighting is required in the building.
- Review the fire risk assessment.
- Identify all escape routes and exit signs.
- Check whether the current system matches the building layout.
- Assign routine checks to a suitable person.
- Complete and record monthly functional tests.
- Arrange an annual full-duration test.
- Keep certificates and repair records together.
- Investigate every failed fitting.
- Retest equipment after repairs.
- Review emergency lighting after refurbishment or layout changes.
- Coordinate testing with other planned maintenance.
- Ask a competent contractor to review unclear or incomplete records.

Arrange emergency lighting testing in North Wales
A clear emergency lighting schedule helps protect occupants and supports responsible property management.
If you need emergency lighting testing, electrical testing services or planned preventative maintenance, contact Dragon Security & Electrical Ltd. We support landlords, letting agents, property managers and businesses across Conwy, Denbighshire, North Wales and beyond.
Call 01492 330330 or visit the Dragon Security & Electrical contact page to discuss your requirements.
Related service: Commercial electricians and electrical services in North Wales.